File and project problems
A sample will not load
Check:- the file still exists at the same path
- the format is supported
- the path is not from a disconnected external drive or moved directory
A Windows drive will not open
An assigned drive letter can refer to removable media with no disk inserted or to a disconnected network share. Meiji Sampler lists assigned letters without reading every drive. An error when opening a drive keeps the browser in its previous state. Reconnect the device or share, go up to Windows drives, then press [BACKSPACE] / [←] again to refresh the drive list. Select the drive and retry with [ENTER]. See Browse.A project will not save
Check:- the projects directory is writable
- the target filename is valid
- you are not unintentionally colliding with another project name
- the disk is not full
- the save location has not moved underneath the app
~/Documents/Meiji Sampler/Projects/
A project seems corrupt
The project loader attempts backup recovery using.bak files when possible.
If the primary file fails to parse, the app may still recover the backup version of the same project.
If a recovered project opens, save it immediately under a new name before continuing.
My session changed after restart
Remember that there are two different persistence layers:- background session state
- explicit
.meijiproject files
Recover a DJ recording partial
An overflow, tap failure, disk error, or finalization error can leaveDJ Set ... .partial in Bounces. Meiji Sampler keeps this file so you can attempt recovery, but it never announces or scans it as a completed bounce.
- Stop Meiji Sampler and make a copy of the
.partialfile before working on it. - Open the copy in an audio editor that can import and rewrite incomplete WAV data.
- Export the recovered audio under a new
.wavname. - Leave the original
.partialunchanged until you have verified the new file.
.wav. A failed finalization can leave WAV metadata incomplete even when much of the audio data was written. See DJ Mode for the source captured by DJ master recording and Storage Paths for the folder.
Uninstall cleanup
Deleting the application uninstalls Meiji Sampler without deleting packs, recordings, exports, settings, or preferences. To fully remove the application and all its data:- Delete the application itself.
- Delete the config, data, and cache directories for your platform. See Storage Paths for the exact paths.
Fast rule of thumb
If the problem is about something not opening, not saving, or not being where you expected, check the path first.Related pages
Crop, WARP, or sample undo fails
The previous pad stays assigned when preparation fails or is cancelled. Check that the source is a readable mono/stereo audio file, trim bounds select at least one frame, and configuration storage is writable with sufficient space. Retry after cancelling preparation has finished. Do not deletesample-edits while its paths
are live in a session.
A named-project save refuses missing live edit/undo assets before replacing its
existing JSON. Restore the missing asset or reload the last saved project with its
sibling .assets directory. Always move that directory with the .meiji file.
Extra retained assets after an unsuccessful save are safe; do not remove files that
a previous project or backup may still reference.